Packages: 54
Sample type: Waste/construction material
Analysis type: Leaching tests
Leaching tests / Waste/construction material
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-1 (L/S 2, 4mm) |
Leaching test according to EN 12457-1, LS/2 (4 mm)
Package info
Price: 2 320 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in one step: firstly at L/S 2 for 24 hours and then at L/S 8 for 18 hours. The total leaching time is 24 hours and the accumulated L/S ratio is 10. After filtering, the leachates are analyzed separately.
Leachate analyses not included in the price.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) |
Leaching test according to EN 12457-2, LS/10 (4 mm)
Package info
Price: 2 320 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in one step: at L/S 10 for 24 hours. After filtering, the leachates are analyzed separately.
Leachate analyses not included in the price.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) |
Leaching test according to EN 12457-3, LS/2 and LS/10 (4 mm)
Package info
Price: 3 225 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in two steps: firstly at L/S 2 for 6 hours and then at L/S 8 for 18 hours. The total leaching time is 24 hours and the accumulated L/S ratio is 10. After filtering, the leachates are analyzed separately.
Leachate analyses not included in the price.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-4 (L/S 10, 10mm) |
Leaching test according to EN 12457-4, LS/10 (10 mm)
Package info
Price: 2 320 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 10 mm and shaken with deionized water in one step: at L/S 10 for 24 hours. After filtering, the leachates are analyzed separately.
Leachate analyses not included in the price.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
Analysis of substance: | Report limit: |
---|---|
Percolation test (column test) L/S 0.1 & 10 |
Percolation test (5 cm diameter column) according to SIS-CEN/TS 14405
Package info
Price: 11 070 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 5 kg
Express: No
Accreditation: Yes
Remarks: A sample is sieved (or crushed) at <4 mm or <10 mm depending on column diameter. The sample is packed and leached while continuously increasing the L/S ratio by slowly pumping in deionized water from the bottom of the column. Maximum 7 leachates are extracted from the column at the L/S ratios 0.1, 0.2, 0.5, 1, 2, 5 and 10. The leachates are analyzed separately. Leachate analyses not included in the price.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Percolation test (column test) L/S 0.1 & 10 |
Percolation test (10 cm diameter column) according to SIS-CEN/TS 14405
Package info
Price: 12 220 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 5 kg
Express: No
Accreditation: Yes
Remarks: A sample is sieved (or crushed) at <4 mm or <10 mm depending on column diameter. The sample is packed and leached while continuously increasing the L/S ratio by slowly pumping in deionized water from the bottom of the column. Maximum 7 leachates are extracted from the column at the L/S ratios 0.1, 0.2, 0.5, 1, 2, 5 and 10. The leachates are analyzed separately. Leachate analyses not included in the price.
For more information about leach testing and analysis of waste.
The TAT can be longer (up to 16 weeks) depending on the properties of the material. Please contact us for more information.
Analysis of substance: | Report limit: |
---|---|
TOC | 0.1 % |
TOC in waste and building material
Package info
Price: 650 SEK / sampleStd. response time: 10 work days
Fastest response time: 3 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Method: According to SS-EN 13137.
Express: Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Accreditation: Yes
Remarks: Included in criteria for all waste types except for stable non-reactive hazardous waste deposited at landfill/cell for non-hazardous waste.
For more information about leach testing and analysis of waste.
Cost for sample preparation may be added.
If you have questions about sample preparation, please contact the laboratory.
Analysis of substance: | Report limit: |
---|---|
pH | 3-13 pH |
pH in construction material
Package info
Price: 390 SEK / sampleDiscount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Remarks: Included only in criteria for stable non-reactive hazardous waste accepted at landfills for non-hazardous waste
For more information about leach testing and analysis of waste.
Cost for sample preparation may be added.
If you have questions about sample preparation, please contact the laboratory.
Analysis of substance: | Report limit: |
---|---|
Al, aluminium | 2 µg/l |
As, arsenic 1 | 1 µg/l |
Ba, barium | 0.2 µg/l |
Ca, calcium | 200 µg/l |
Cd, cadmium 2 | 0.05 µg/l |
Co, cobalt | 0.05 µg/l |
Cr, chromium | 0.5 µg/l |
Cu, copper | 1 µg/l |
Fe, iron | 4 µg/l |
Hg, mercury | 0.02 µg/l |
K, potassium | 500 µg/l |
Mg, magnesium | 90 µg/l |
Mn, manganese | 0.2 µg/l |
Mo, molybdenum | 1 µg/l |
Na, sodium | 200 µg/l |
Ni, nickel | 0.5 µg/l |
Pb, lead | 0.2 µg/l |
Sb, antimony | 0.1 µg/l |
Se, selenium 3 | 2.5 µg/l |
Zn, zinc | 2 µg/l |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | 3-11 pH |
conductivity | 1 mS/m |
LV-3a Leachate, no digestion
Package info
Price: 2 570 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: min. 60 ml
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: Supplementary element outside the accreditation: Sulphur requires special digestion. Contact laboratory for price (SEK).
For more information about leach testing and analysis of waste.
1 Analysis of As is performed using high resolution technique within the accreditation.
2 A higher limit of quantification applies to samples with high molybdenum levels.
3 Analysis of Se is performed using high resolution technique within the accrediation. A lower limit of reporting (0.008 ug/l) can be obtained after digestion with HCl in autoclave (non-accredited analysis).
Analysis of substance: | Report limit: |
---|---|
As, arsenic 1 | 1 µg/l |
Ba, barium | 0.2 µg/l |
Cd, cadmium 2 | 0.05 µg/l |
Cr, chromium | 0.5 µg/l |
Cu, copper | 1 µg/l |
Hg, mercury | 0.02 µg/l |
Mo, molybdenum | 1 µg/l |
Ni, nickel | 0.5 µg/l |
Pb, lead | 0.2 µg/l |
Sb, antimony | 0.1 µg/l |
Se, selenium 3 | 2.5 µg/l |
Zn, zinc | 2 µg/l |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | 3-11 pH |
conductivity | 1 mS/m |
LV-4a Leachate, analysis without digestion
Package info
Price: 2 040 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Container: 2x250 ml plastic bottle + 60 ml plastic bottle
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: Supplementary element outside the accreditation: Sulphur requires special digestion. Contact laboratory for price (SEK).
For more information about leach testing and analysis of waste.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
Exprassanalysis with shorter TAT can be offered in combination with leaching tests (one step). Please contact the laboratory in Luleå for information.
1 Analysis of As is performed using high resolution technique within the accreditation.
2 A higher limit of quantification applies to samples with high molybdenum levels.
3 Analysis of Se is performed using high resolution technique within the accrediation. A lower limit of reporting (0.008 ug/l) can be obtained after digestion with HCl in autoclave (non-accredited analysis).
Analysis of substance: | Report limit: |
---|---|
Al, aluminium | 2 µg/l |
Be, beryllium 1 | 0.5 µg/l |
B, boron | 20 µg/l |
Cs, cesium 1 | 0.05 µg/l |
Fe, iron | 0.004 mg/l |
Li, lithium | 10 µg/l |
Mn, manganese | 0.2 µg/l |
P, phosphorus | 10 µg/l |
Rb, rubidium 1 | 0.01 µg/l |
Si, silicon | 0.4 mg/l |
Sr, strontium | 10 µg/l |
S, sulphur | 0.2 mg/l |
Tl, thallium | 0.1 µg/l |
Sn, tin | 0.5 µg/l |
Ti, titanium 1 | 0.01 µg/l |
U, uranium | 0.01 µg/l |
V, vanadium | 0.05 µg/l |
Zr, zirconium 1 | 0.01 µg/l |
LV-3a-ADD Supplementary elements
Package info
Price: 2 580 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Remarks: For more information about leach testing and analysis of waste.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
1 The parameter is not accredited.
Analysis of substance: | Report limit: |
---|---|
phenol index |
Phenol index for leachate
Package info
Price: 775 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Remarks: Included only in criteria for inert waste accepted at landfills for inert waste
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
TS for dissolved compounds |
Total dissolved solids in leaching water
Package info
Price: 415 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Remarks: For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
naphthalene | 0.1 mg/kg |
acenaphthylene | 0.3 mg/kg |
acenaphthene | 0.05 mg/kg |
fluorene | 0.1 mg/kg |
phenanthrene | 0.1 mg/kg |
anthracene | 0.1 mg/kg |
fluoranthene | 0.1 mg/kg |
pyrene | 0.1 mg/kg |
benzo(a)anthracene | 0.05 mg/kg |
chrysene | 0.05 mg/kg |
benzo(b)fluoranthene | 0.05 mg/kg |
benzo(k)fluoranthene | 0.05 mg/kg |
benzo(a)pyrene | 0.05 mg/kg |
dibenzo(ah)anthracene | 0.05 mg/kg |
benzo(ghi)perylene | 0.1 mg/kg |
indeno(123cd)pyrene | 0.05 mg/kg |
sum of 16 PAHs | 0.4 mg/kg |
sum of other PAHs | 0.2 mg/kg |
sum of carcinogenic PAH | 0.3 mg/kg |
PCB 28 | 0.003 mg/kg |
PCB 138 | 0.003 mg/kg |
PCB 52 | 0.003 mg/kg |
PCB 153 | 0.003 mg/kg |
PCB 101 | 0.003 mg/kg |
PCB 180 | 0.003 mg/kg |
PCB 118 | 0.003 mg/kg |
sum PCB 7 | 0.01 mg/kg |
benzene | 0.2 mg/kg |
sum of xylenes | 0.50 mg/kg |
toluene | 0.20 mg/kg |
ethylbenzene | 0.20 mg/kg |
oil index >C10-C40 | 50 mg/kg |
LOJ-1 Analysis of inert solid material
Package info
Price: 3 405 SEK / sampleStd. response time: 10 work days
Fastest response time: 2 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: 50 g dry matter
Container: Soil: diffusion tight plastic bag. Sludge/sediment 212 ml/720 ml glass jar or 2,3 l plastic bucket
Method: GC-FID/GC-MS
Express: Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Accreditation: Yes
Remarks: Total concentration analyses on inert material according to NFS 2004:10.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
ANC |
ANC (alkalinity)
Package info
Price: 1 885 SEK / sampleStd. response time: 10 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: 100 g dry matter
Container: 100 ml plastic jar
Express: Yes, Express tariff 2: 3 days +100%; 4 days +75%; 5 days +40%; 6 days +30%; 7 days +20%
Accreditation: No
Remarks: Included in criteria for stable non-reactive hazardous waste accepted at landfills for non-hazardous waste; and for landfills for hazardous waste
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Following steps will be performed: | |
1. Adsorbed and exchangable metals, carbonates (1.0 M Na-acetate buffer) | |
2. Labil organic forms (0.1 M Na-pyro phosphate) | |
3. Amorph Fe/Mn-oxids (0.25 M NH2OH·HCl in 0.1 M HCl in 60°C ) | |
4. Cristallic ferric oxids (1.0 M NH2OH·HCl in 25% acetic acid in 90°C ) | |
5. Stable organic forms, sulphides (K-chlorate in 12 M HCl,4 M HNO3 in 90°) |
Sek-Lak Sequential leaching 5 steps
Package info
Price: 10 020 SEK / sampleStd. response time: 20 work days
Fastest response time: 4 work days
Sample type: Waste/construction material
Analysis type: Leaching tests
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: No
Remarks: For more information, we refer to ALS Scandinavia Luleå.
Analysis of Na, K and P cannot be ordered.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-1 (L/S 2, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity |
LAK-1 Leaching test EN 12457-1 (L/S 2, 4mm) + analysis (LV-4a)
Package info
Price: 4 410 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in one step: firstly at L/S 2 for 24 hours and then at L/S 8 for 18 hours. The total leaching time is 24 hours and the accumulated L/S ratio is 10. After filtering, the leachates are analyzed separately.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
ANC |
LAK-6a Leaching test and analysis of hazardous waste not regularly generated, according to recommendations in NFS 2004:10
Package info
Price: 9 580 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
ANC |
LAK-5a Leaching test (one step) and analysis of hazardous waste according to recommendations in NFS 2004:10
Package info
Price: 6 700 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
phenol index | |
Analysis of solid material: | |
Analytical package LOJ-1 | |
TOC | 0.1 % |
LAK-6c Leaching test and analysis of inert waste not regularly generated, according to recommendations in NFS 2004:10
Package info
Price: 12 730 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: För scope of analysis of LOJ-1, please click here.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity |
LAK-2 Leaching test EN 12457-2 (L/S 10, 4mm) + analysis (LV-4a)
Package info
Price: 4 285 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in one step: at L/S 10 for 24 hours. After filtering, the leachates are analyzed separately.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity |
LAK-3 Leaching test EN 12457-3 (L/S 2 & 10, 4mm) + analysis (LV-4a)
Package info
Price: 7 395 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in two steps: firstly at L/S 2 for 6 hours and then at L/S 8 for 18 hours. The total leaching time is 24 hours and the accumulated L/S ratio is 10. After filtering, the leachates are analyzed separately.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-4 (L/S 10, 10mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity |
LAK-4 Leaching test EN 12457-4 (L/S 10, 10mm) + analysis (LV-4a)
Package info
Price: 4 410 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 10 mm and shaken with deionized water in one step: at L/S 10 for 24 hours. After filtering, the leachates are analyzed separately.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Al, aluminium | 2 µg/l |
Be, beryllium 1 | 0.5 µg/l |
Co, cobalt | 0.05 µg/l |
Cs, cesium 1 | 0.05 µg/l |
Fe, iron | 0.004 mg/l |
Mn, manganese | 0.2 µg/l |
P, phosphorus | 10 µg/l |
Rb, rubidium 1 | 0.01 µg/l |
Tl, thallium | 0.1 µg/l |
Sn, tin | 0.5 µg/l |
Ti, titanium 1 | 0.01 µg/l |
U, uranium | 0.01 µg/l |
V, vanadium | 0.05 µg/l |
LV-4a-ADD Supplementary elements
Package info
Price: See remarks.Std. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: min. 60 ml
Method: ICP-MS
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: Price for single element analysis: 425 SEK. Subsequent elements: 230 SEK/element. Request a quote when ordering of more than 5 elements.
For more information about leach testing and analysis of waste.
1 The parameter is not accredited.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
LAK-6b Leaching test and analysis of non-hazardous waste not regularly generated, according to recommendations in NFS 2004:10
Package info
Price: 7 720 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
LAK-5b Leaching test (one step) and analysis of non-hazardous waste according to recommendations in NFS 2004:10
Package info
Price: 4 850 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
phenol index | |
Analysis of solid material: | |
Analytical package LOJ-1 | |
TOC | 0.1 % |
LAK-5c Leaching test (one step) and analysis of inert waste according to recommendations in NFS 2004:10
Package info
Price: 9 860 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: För scope of analysis of LOJ-1, please click here.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Percolation test (column test) L/S 0.1 & 10 | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
ANC |
LAK-7a Percolation test and analysis of hazardous waste according to recommendations in NFS 2004:10
Package info
Price: 17 100 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 5 kg
Express: No
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Percolation test (column test) L/S 0.1 & 10 | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
LAK-7b Percolation test and analysis of non-hazardous waste according to recommendations in NFS 2004:10
Package info
Price: 15 250 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 5 kg
Express: No
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Percolation test (column test) L/S 0.1 & 10 | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
phenol index | |
Analysis of solid material: | |
Analytical package LOJ-1 | |
TOC | 0.1 % |
LAK-7c Percolation test and analysis of inert waste according to recommendations in NFS 2004:10
Package info
Price: 20 240 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 3 kg
Container: 2 x 2,3 L plastic bucket
Accreditation: Yes
Remarks: För scope of analysis of LOJ-1, please click here.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Percolation test (column test) L/S 0.1 & 10 | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
ANC |
LAK-8a Leaching tests and analyses for basic characterization of hazardous waste, according to recommendations in NFS 2004:10
Package info
Price: 23 945 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 3 kg
Container: 2 x 2,3 L plastic bucket
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Percolation test (column test) L/S 0.1 & 10 | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Cu, copper | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
Analysis of solid material: | |
TOC | 0.1 % |
LAK-8b Leaching tests and analyses for basic characterization of non-hazardous waste, according to recommendations in NFS 2004:10
Package info
Price: 22 100 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 3 kg
Container: 2 x 2,3 L plastic bucket
Express: No
Accreditation: Yes
Remarks: For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Percolation test (column test) L/S 0.1 & 10 | |
Leaching water analysis acc. to LV-4a: | |
As, arsenic | |
Ba, barium | |
Cd, cadmium | |
Cr, chromium | |
Hg, mercury | |
Mo, molybdenum | |
Ni, nickel | |
Pb, lead | |
Sb, antimony | |
Se, selenium | |
Zn, zinc | |
chloride | |
fluoride | |
sulfate | |
DOC (dissolved organic carbon) | |
pH | |
conductivity | |
phenol index | |
Analysis of solid material: | |
Analytical package LOJ-1 | |
TOC | 0.1 % |
LAK-8c Leaching tests and analyses for basic characterization of inert waste, according to recommendations in NFS 2004:10
Package info
Price: 27 000 SEK / sampleStd. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests > Leaching tests
Sample amount: approx. 3 kg
Container: 2 x 2,3 L plastic bucket
Accreditation: Yes
Remarks: För scope of analysis of LOJ-1, please click here.
For certain types of sludge and clayey materials that are difficult to filter, only the L/S 10-leaching will be performed.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
Analysis of substance: | Report limit: |
---|---|
Al, aluminium | 2 µg/l |
As, arsenic 1 | 0.5 µg/l |
Ba, barium | 0.2 µg/l |
Ca, calcium | 200 µg/l |
Cd, cadmium 2 | 0.05 µg/l |
Co, cobalt | 0.05 µg/l |
Cr, chromium | 0.5 µg/l |
Cu, copper | 1 µg/l |
Fe, iron | 4 µg/l |
Hg, mercury | 0.02 µg/l |
Mg, magnesium | 90 µg/l |
Mn, manganese | 0.2 µg/l |
Mo, molybdenum | 0.5 µg/l |
Ni, nickel | 0.5 µg/l |
Pb, lead | 0.2 µg/l |
V, vanadium | 0.05 µg/l |
Zn, zinc | 2 µg/l |
Sek-V-3a Metal analysis of leachate from sequential leaching
Package info
Price: 1 300 SEK / sampleStd. response time: 20 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: min. 5 g
Container: 100 ml plastic jar
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: Analysis of Na, K and P cannot be ordered.
1 A higher limit of quantification applies to samples with high chloride levels.
2 A higher limit of quantification applies to samples with high molybdenum levels.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Leaching water analysis acc. to OV-34bQ: | |
PFBA Perfluoro-n-butanoic acid | 0.002 µg/l |
PFPeA Perfluoro-n-pentanoic acid | 0.0003 µg/l |
PFHxA Perfluoro-n-hexanoic acid | 0.0003 µg/l |
PFHpA Perfluoro-n-heptanoic acid | 0.0003 µg/l |
PFOA Perfluoro-n-octanoic acid | 0.0003 µg/l |
PFNA Perfluoro-n-nonanoic acid | 0.0003 µg/l |
PFDA Perfluoro-n-decanoic acid | 0.0003 µg/l |
PFBS Perfluorobutanesulfonic acid | 0.0003 µg/l |
PFHxS Perfluorohexanesulfonic acid 1 | 0.0003 µg/l |
PFOS Perfluorooctanesulfonic acid 1 | 0.0003 µg/l |
6:2 FTS 6:2 fluorotelomer sulfonic acid | 0.0003 µg/l |
PFAS, sum 4 | µg/l |
PFAS, sum 11 | µg/l |
PFUnDA Perfluoro-n-undecanoic acid | 0.0003 µg/l |
PFDoDA Perfluoro-n-dodecanoic acid | 0.0003 µg/l |
PFTrDA Perfluoro-n-tridecanoic acid | 0.0003 µg/l |
PFPeS perfluoropentanesulfonic acid | 0.0003 µg/l |
PFHpS Perfluoroheptanesulfonic acid | 0.0003 µg/l |
PFNS perfluorononane sulfonic acid | 0.0003 µg/l |
PFDS Perfluorodecanesulfonic acid | 0.0003 µg/l |
PFUnDS perfluoroundecane sulfonic acid | 0.0003 µg/l |
PFDoDS Perfluorodecane sulfonic acid | 0.001 µg/l |
PFTrDS perfluorotridecane sulfonic acid | 0.001 µg/l |
PFAS, sum 20 | µg/l |
PFAS, sum 21 | µg/l |
Other compounds: | |
pH | |
conductivity |
LAK-9a Leaching test EN 12457-3 + (L/S 2 & 10, 4mm) + analysis OV-34bQ PFAS (21) (low LOQ)
Package info
Price: 9 670 SEK / sampleStd. response time: 15 work days
Fastest response time: 5 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in two steps: firstly at L/S 2 for 6 hours and then at L/S 8 for 18 hours. The total leaching time is 24 hours and the accumulated L/S ratio is 10. After decantation, the leachates are analysed separately.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
1 Reported as sum of linear and branched. The other parameters are reported as linear.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) | |
Leaching water analysis acc. to OV-34bQ: | |
PFBA Perfluoro-n-butanoic acid | 0.002 µg/l |
PFPeA Perfluoro-n-pentanoic acid | 0.0003 µg/l |
PFHxA Perfluoro-n-hexanoic acid | 0.0003 µg/l |
PFHpA Perfluoro-n-heptanoic acid | 0.0003 µg/l |
PFOA Perfluoro-n-octanoic acid | 0.0003 µg/l |
PFNA Perfluoro-n-nonanoic acid | 0.0003 µg/l |
PFDA Perfluoro-n-decanoic acid | 0.0003 µg/l |
PFBS Perfluorobutanesulfonic acid | 0.0003 µg/l |
PFHxS Perfluorohexanesulfonic acid 1 | 0.0003 µg/l |
PFOS Perfluorooctanesulfonic acid 1 | 0.0003 µg/l |
6:2 FTS 6:2 fluorotelomer sulfonic acid | 0.0003 µg/l |
PFAS, sum 4 | µg/l |
PFAS, sum 11 | µg/l |
PFUnDA Perfluoro-n-undecanoic acid | 0.0003 µg/l |
PFDoDA Perfluoro-n-dodecanoic acid | 0.0003 µg/l |
PFTrDA Perfluoro-n-tridecanoic acid | 0.0003 µg/l |
PFPeS perfluoropentanesulfonic acid | 0.0003 µg/l |
PFHpS Perfluoroheptanesulfonic acid | 0.0003 µg/l |
PFNS perfluorononane sulfonic acid | 0.0003 µg/l |
PFDS Perfluorodecanesulfonic acid | 0.0003 µg/l |
PFUnDS perfluoroundecane sulfonic acid | 0.0003 µg/l |
PFDoDS Perfluorodecane sulfonic acid | 0.001 µg/l |
PFTrDS perfluorotridecane sulfonic acid | 0.001 µg/l |
PFAS, sum 20 | µg/l |
PFAS, sum 21 | µg/l |
Other compounds: | |
pH | |
conductivity |
LAK-9c Leaching test EN 12457-2 (L/S 10, 4mm) + analysis OV-34bQ PFAS (21) (low LOQ)
Package info
Price: 5 450 SEK / sampleStd. response time: 15 work days
Fastest response time: 4 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in one step: at L/S 10 for 24 hours. After decantation, the leachates are analyzed separately.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
1 Reported as sum of linear and branched. The other parameters are reported as linear.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-3 (L/S 2 & 10, 4mm) | |
Leaching water analysis acc. to OV-34dQ: | |
PFBA Perfluoro-n-butanoic acid | 0.002 µg/l |
PFPeA Perfluoro-n-pentanoic acid | 0.0003 µg/l |
PFHxA Perfluoro-n-hexanoic acid | 0.0003 µg/l |
PFHpA Perfluoro-n-heptanoic acid | 0.0003 µg/l |
PFOA Perfluoro-n-octanoic acid | 0.0003 µg/l |
PFNA Perfluoro-n-nonanoic acid | 0.0003 µg/l |
PFDA Perfluoro-n-decanoic acid | 0.0003 µg/l |
PFBS Perfluorobutanesulfonic acid | 0.0003 µg/l |
PFHxS Perfluorohexanesulfonic acid 1 | 0.0003 µg/l |
PFOS Perfluorooctanesulfonic acid 1 | 0.0003 µg/l |
6:2 FTS 6:2 fluorotelomer sulfonic acid | 0.0003 µg/l |
PFAS, sum 4 | µg/l |
PFAS, sum 11 | µg/l |
PFUnDA Perfluoro-n-undecanoic acid | 0.0003 µg/l |
PFDoDA Perfluoro-n-dodecanoic acid | 0.0003 µg/l |
PFTrDA Perfluoro-n-tridecanoic acid | 0.0003 µg/l |
PFPeS perfluoropentanesulfonic acid | 0.0003 µg/l |
PFHpS Perfluoroheptanesulfonic acid | 0.0003 µg/l |
PFNS perfluorononane sulfonic acid | 0.0003 µg/l |
PFDS Perfluorodecanesulfonic acid | 0.0003 µg/l |
PFUnDS perfluoroundecane sulfonic acid | 0.001 µg/l |
PFTrDS perfluorotridecane sulfonic acid | 0.001 µg/l |
PFDoDS Perfluorodecane sulfonic acid | 0.0003 µg/l |
PFAS, sum 20 | µg/l |
PFAS, sum 21 | µg/l |
4:2 FTS fluorotelomer sulfonic acid | 0.0003 µg/l |
8:2 FTS fluorotelomer sulfonate | 0.0003 µg/l |
PFOSA Perfluorooctanesulfonamide | 0.0003 µg/l |
MeFOSA N-methyl perfluorooctane sulfonamide | 0.002 µg/l |
EtFOSA N-ethyl perfluorooctane sulfonamide | 0.002 µg/l |
MeFOSE N-methyl perfluorooctane sulfonamidoethanol | 0.002 µg/l |
EtFOSE N-ethyl perfluorooctane sulfonamidoethanol | 0.002 µg/l |
FOSAA perfluorooctane sulfonamidoacetic acid | 0.001 µg/l |
MeFOSAA N-methylperfluorooctanesulfonamido acid | 0.001 µg/l |
EtFOSAA N-ethylperfluorooctanesulfonamido acid | 0.001 µg/l |
HPFHpA 7H-perflouroheptanic acid | 0.001 µg/l |
PF37DMOA perfluoro-3,7-dimethyloctanic acid | 0.001 µg/l |
PFTeDA perfluoro-n-tetradecanoic acid | 0.0003 µg/l |
Perfluoro-4-methoxybutanoic acid (PFMBA) | 0.001 µg/l |
Perfluoro-3-methoxypropanoic acid (PFMPA) | 0.001 µg/l |
11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS) | 0.001 µg/l |
9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS) | 0.001 µg/l |
4,8-dioxa-3H-perfluorononanoic acid (DONA) | 0.002 µg/l |
PFPrS Perfluoropropanesulfonic acid | 0.001 µg/l |
2,3,3,3-tetrafluoro-2-(heptafluoropropoxy)propanoic acid (HFPO-DA) (Gen-X) | 0.001 µg/l |
2H,2H,3H,3H-perfluoroundecanoic acid (H4PFUnDA) | 0.0003 µg/l |
7:3 FTCA 2H,2H,3H,3H-perfluorodecanoic acid | 0.0003 µg/l |
8:2 FTCA 2H,2H-perfluorodecanoic acid | 0.001 µg/l |
3:3 FTCA 2H,2H,3H,3H-perfluorohexanoic acid | 0.0003 µg/l |
PFEESA Perfluoro(2-ethoxyethane)sulfonic acid | 0.001 µg/l |
6:2 FTCA 2H,2H-perfluorooctanoic acid | 0.001 µg/l |
PFECHS Perfluoro-4-ethylcyclohexanesulfonic acid | 0.0003 µg/l |
5:3 FTCA 2H,2H,3H,3H-perfluorooctanoic acid | 0.001 µg/l |
6:2 FTUCA 2H-perfluoro-2-octenoic acid | 0.001 µg/l |
8:2 FTUCA 2H-perfluoro-2-decenoic acid | 0.001 µg/l |
Other compounds: | |
pH | |
conductivity |
LAK-9b Leaching test EN 12457-3 + (L/S 2 & 10, 4mm) + analysis OV-34dQ PFAS (51) (Low LOR)
Package info
Price: 14 565 SEK / sampleStd. response time: 15 work days
Fastest response time: 8 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in two steps: firstly at L/S 2 for 6 hours and then at L/S 8 for 18 hours. The total leaching time is 24 hours and the accumulated L/S ratio is 10. After decantation, the leachates are analysed separately.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
1 Reported as sum of linear and branched. The other parameters are reported as linear.
Analysis of substance: | Report limit: |
---|---|
Leaching test EN 12457-2 (L/S 10, 4mm) | |
Leaching water analysis acc. to OV-34dQ: | |
PFBA Perfluoro-n-butanoic acid | 0.002 µg/l |
PFPeA Perfluoro-n-pentanoic acid | 0.0003 µg/l |
PFHxA Perfluoro-n-hexanoic acid | 0.0003 µg/l |
PFHpA Perfluoro-n-heptanoic acid | 0.0003 µg/l |
PFOA Perfluoro-n-octanoic acid | 0.0003 µg/l |
PFNA Perfluoro-n-nonanoic acid | 0.0003 µg/l |
PFDA Perfluoro-n-decanoic acid | 0.0003 µg/l |
PFBS Perfluorobutanesulfonic acid | 0.0003 µg/l |
PFHxS Perfluorohexanesulfonic acid 1 | 0.0003 µg/l |
PFOS Perfluorooctanesulfonic acid 1 | 0.0003 µg/l |
6:2 FTS 6:2 fluorotelomer sulfonic acid | 0.0003 µg/l |
PFAS, sum 4 | µg/l |
PFAS, sum 11 | µg/l |
PFUnDA Perfluoro-n-undecanoic acid | 0.0003 µg/l |
PFDoDA Perfluoro-n-dodecanoic acid | 0.0003 µg/l |
PFTrDA Perfluoro-n-tridecanoic acid | 0.0003 µg/l |
PFPeS perfluoropentanesulfonic acid | 0.0003 µg/l |
PFHpS Perfluoroheptanesulfonic acid | 0.0003 µg/l |
PFNS perfluorononane sulfonic acid | 0.0003 µg/l |
PFDS Perfluorodecanesulfonic acid | 0.0003 µg/l |
PFUnDS perfluoroundecane sulfonic acid | 0.001 µg/l |
PFTrDS perfluorotridecane sulfonic acid | 0.001 µg/l |
PFDoDS Perfluorodecane sulfonic acid | 0.0003 µg/l |
PFAS, sum 20 | µg/l |
PFAS, sum 21 | µg/l |
4:2 FTS fluorotelomer sulfonic acid | 0.0003 µg/l |
8:2 FTS fluorotelomer sulfonate | 0.0003 µg/l |
PFOSA Perfluorooctanesulfonamide | 0.0003 µg/l |
MeFOSA N-methyl perfluorooctane sulfonamide | 0.002 µg/l |
EtFOSA N-ethyl perfluorooctane sulfonamide | 0.002 µg/l |
MeFOSE N-methyl perfluorooctane sulfonamidoethanol | 0.002 µg/l |
EtFOSE N-ethyl perfluorooctane sulfonamidoethanol | 0.002 µg/l |
FOSAA perfluorooctane sulfonamidoacetic acid | 0.001 µg/l |
MeFOSAA N-methylperfluorooctanesulfonamido acid | 0.001 µg/l |
EtFOSAA N-ethylperfluorooctanesulfonamido acid | 0.001 µg/l |
HPFHpA 7H-perflouroheptanic acid | 0.001 µg/l |
PF37DMOA perfluoro-3,7-dimethyloctanic acid | 0.001 µg/l |
PFTeDA perfluoro-n-tetradecanoic acid | 0.0003 µg/l |
Perfluoro-4-methoxybutanoic acid (PFMBA) | 0.001 µg/l |
Perfluoro-3-methoxypropanoic acid (PFMPA) | 0.001 µg/l |
11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS) | 0.001 µg/l |
9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS) | 0.001 µg/l |
4,8-dioxa-3H-perfluorononanoic acid (DONA) | 0.002 µg/l |
PFPrS Perfluoropropanesulfonic acid | 0.001 µg/l |
2,3,3,3-tetrafluoro-2-(heptafluoropropoxy)propanoic acid (HFPO-DA) (Gen-X) | 0.001 µg/l |
2H,2H,3H,3H-perfluoroundecanoic acid (H4PFUnDA) | 0.0003 µg/l |
7:3 FTCA 2H,2H,3H,3H-perfluorodecanoic acid | 0.0003 µg/l |
8:2 FTCA 2H,2H-perfluorodecanoic acid | 0.001 µg/l |
3:3 FTCA 2H,2H,3H,3H-perfluorohexanoic acid | 0.0003 µg/l |
PFEESA Perfluoro(2-ethoxyethane)sulfonic acid | 0.001 µg/l |
6:2 FTCA 2H,2H-perfluorooctanoic acid | 0.001 µg/l |
PFECHS Perfluoro-4-ethylcyclohexanesulfonic acid | 0.0003 µg/l |
5:3 FTCA 2H,2H,3H,3H-perfluorooctanoic acid | 0.001 µg/l |
6:2 FTUCA 2H-perfluoro-2-octenoic acid | 0.001 µg/l |
8:2 FTUCA 2H-perfluoro-2-decenoic acid | 0.001 µg/l |
Other compounds: | |
pH | |
conductivity |
LAK-9d Leaching test EN 12457-2 (L/S 10, 4mm) + analysis OV-34dQ PFAS (51) (Low LOR)
Package info
Price: 7 850 SEK / sampleStd. response time: 15 work days
Fastest response time: 7 work days
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 2 kg
Container: 2,3 L plastic bucket
Express: Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Accreditation: Yes
Remarks: A sample is sieved at 4 mm and shaken with deionized water in one step: at L/S 10 for 24 hours. After decantation, the leachates are analyzed separately.
Please always contact customer service in Luleå before samples for express analyses are sent to the laboratory.
For more information about leach testing and analysis of waste.
1 Reported as sum of linear and branched. The other parameters are reported as linear.