Packages: 58
Sample type: Air/Work environment
Analysis type: Asbestos and fibers, Mold and dry rot fungus, Microplastics and particles, Equipment, Elements, Organic compounds
Asbestos and fibers / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
fibers |
A-1a Fiber counting in filter samples
Package info
1 850 SEK / sample15 work days
6
Air/Work environment
Asbestos and fibers
recommended volume 100-500 liters, flow rate 2 l/min
mixed cellulose filter
Polarization microscopy (PLM) with phase contrast
No
Yes
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
Recommeded sampling volume is given by client when analysis is ordered
Analysis of substance: | Report limit: |
---|---|
Asbestos fibers | 0,01 fibre/cm3 |
A-2a Asbestos fiber counting and identification on air filter
Package info
2 140 SEK / sample10 work days
Same day
6
Air/Work environment
Asbestos and fibers
Recommended volume 960L
Polycarbonate filter in monitor for SEM, 25 mm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Read more about asbestos at asbestos-laboratory.com.
Analysis of substance: | Report limit: |
---|---|
Synthetic inorganic fibers | 4 fibres/mm^2 |
Special fibres | 4 fibres/mm^2 |
Ceramic fibers | 4 fibres/mm^2 |
Asbestos fibers | 4 fibres/mm^2 |
A-2f Fiber counting (incl. asbestos) and identification on air filter
Package info
2 140 SEK / sample10 work days
Same day
6
Air/Work environment
Asbestos and fibers
recommended volume 150-400 liters
Polycarbonate filter in monitor for SEM, 25 mm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Read more about asbestos at asbestos-laboratory.com.
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. The fiber types are: Synthetic inorganic fibres, cheramic fibres, special fibres, asbestos fibres.
Mold and dry rot fungus / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Spores | 7 spores/mm2 |
A-3g Moulds and spores on filter samples
Package info
1 820 SEK / sample10 work days
Same day
6
Air/Work environment
Mold and dry rot fungus
Recommende volume 500-1500 liters
Polycarbonate filter in monitor for SEM, 25 mm
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis can only be used to find out if there are spores in the air, not to specify the spores.
Microplastics and particles / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
A-4a Particle determination, quantitative, on filter samples (concentration, size and type)
Package info
3 560 SEK / sample10 work days
Same day
6
Air/Work environment
Microplastics and particles
Recommende volume 500-1500 liters
Polycarbonate filter in monitor for SEM, 25 mm
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
Analysis of substance: | Report limit: |
---|---|
dust | 0.1 mg total |
A-4d Total dust, excl. filter
Package info
360 SEK / sample10 work days
1 work day
6
Air/Work environment
Microplastics and particles
mixed cellulosa filter, pre-weighed, 25/37 mm or filter for inhalable dust, pre-weighed, 25 mm or filter for cyclone, pre-weighed, 25/37 mm Casella alt. 25/37 mm SKC.
Weighing
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Sampling instructions
Additional cost for filter.
Analysis of substance: | Report limit: |
---|---|
quartz | 5 µg/filter |
A-5a Quartz in respirable dust on filter samples, FTIR
Package info
720 SEK / sample10 work days
4 work days
6
Air/Work environment
Microplastics and particles
filter for cyclone (mixed cellulosa) in SKC/Casella cyclone, pre-weighed/unweighed, 25/37mm
FTIR
Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Yes
Sampling instructions
Recommended flow rate 2.2-2.5 l/min, sampling time 8 hrs.
When air volume is submitted, total amount as well as and concentration is reported.
Analysis of substance: | Report limit: |
---|---|
A-5c Quartz, tridymite, and cristobalite on filter samples
Package info
3 630 SEK / sample6
Air/Work environment
Microplastics and particles
PVC filter in SKC-monitor for respirable dust, 25 mm (for quartz, tridymite and kristobalit) incl. sample holder
XRD
Sampling instructions
Minimum sampling volume: 100 l.
Equipment / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Pump kit (AirCheck) for air sampling kit (rental), one week rental
Package info
See remarks.Air/Work environment
Equipment
Yes
For booking of equipment, please visit our webpage.
For samples to be analyzed by ALS Scandinavia, the equipment is delivered to requested address within Sweden free of charge. Quicker deliveries can be offered, shipping costs will be invoiced according to the current price list.
Price/week: 1420 SEK.
Included equipment: bag with calibrated air sampling pump, adapter for pump, tubing, low flow sampling kit. SKC cyclone is not included but available for rent.
Analysis of substance: | Report limit: |
---|---|
Pump kit (AirCheck) for air sampling kit (rental), one day rental
Package info
See remarksAir/Work environment
Equipment
Yes
For booking of equipment, please visit our webpage.
The equipment must be picked up and returned at ALS in Danderyd (Rinkebyvägen 19c) by the customer.
Price/day: 715 SEK
Price for additional days is 245 SEK/day.
Included equipment: bag with calibrated air sampling pump, adapter for pump, tubing, low flow sampling kit. SKC cyclone is not included but available for rent.
Analysis of substance: | Report limit: |
---|---|
Soil gas spear for air sampling (rental), one week rental
Package info
See remarks.Air/Work environment
Equipment
Yes
For booking of equipment, please visit our webpage.
For samples to be analyzed by ALS Scandinavia, the equipment is delivered to requested address within Sweden free of charge. Quicker deliveries can be offered, shipping costs will be invoiced according to the current price list.
Price/week: 1420 SEK.
Analysis of substance: | Report limit: |
---|---|
Soil gas spear for air sampling (rental), one day rental
Package info
See remarks.Air/Work environment
Equipment
Yes
For booking of equipment, please visit our webpage.
For samples to be analyzed by ALS Scandinavia, the equipment is delivered to requested address within Sweden free of charge. Quicker deliveries can be offered, shipping costs will be invoiced according to the current price list.
Price/day: 715 SEK
Price for additional days is 245 SEK/day.
Elements / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
Hg, mercury |
A-6c Mercury on adsorption tubes
Package info
910 SEK / sample10 work days
1 work day
1
Air/Work environment
Elements
charcoal sorbent tube for mercury vapor, SKC 226-17-1A.
ICP
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Sampling instructions
Analysis of substance: | Report limit: |
---|---|
Co, cobalt | 0.0005 µg total |
K, potassium | 50 µg total |
Li, lithium | 0.01 µg total |
Mn, manganese | 0.005 µg total |
Na, sodium | 5 µg total |
Pb, lead | 0.001 µg total |
Sn, tin | 0.005 µg total |
A-6i Metals in inhalable dust
Package info
1 170 SEK / sample10 work days
1 work day
1
Air/Work environment
Elements
ICP
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Price for single element analysis: 615 SEK. Subsequent elements: 230 SEK/element. Request a quote when ordering of more than 5 elements.
More elements can be added, contact us for price information.
Price for single element analysis: 505 SEK. Additional elements are available on request. Price: 190 SEK/supplementary element.
Please contact us for more information about filter types
Analysis of substance: | Report limit: |
---|---|
Al, aluminium | 0.1 µg total |
Ca, calcium | 2 µg total |
Cd, cadmium | 0.0005 µg total |
Cu, copper | 0.02 µg total |
Fe, iron | 0.2 µg total |
Mn, manganese | 0.005 µg total |
Mo, molybdenum | 0.0005 µg total |
Pb, lead | 0.001 µg total |
V, vanadium | 0.001 µg total |
Zn, zinc | 0.5 µg total |
A-6r Metals in respirable dust
Package info
1 230 SEK / sample10 work days
1 work day
1
Air/Work environment
Elements
ICP
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Price for single element analysis: 615 SEK. Subsequent elements: 230 SEK/element. Request a quote when ordering of more than 5 elements.
More elements can be added, contact us for price information.
Please contact us for more information about filter types
Analysis of substance: | Report limit: |
---|---|
Al, aluminium | 0.1 µg total |
As, arsenic | 0.005 µg total |
Ba, barium | 0.01 µg total |
Be, beryllium | 0.0005 µg total |
Cd, cadmium | 0.0005 µg total |
Cr, chromium | 0.01 µg total |
Mo, molybdenum | 0.0005 µg total |
Ni, nickel | 0.005 µg total |
V, vanadium | 0.001 µg total |
Zn, zinc | 0.5 µg total |
A-6t Metals in dust
Package info
1 240 SEK / sample10 work days
1 work day
1
Air/Work environment
Elements
ICP
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Price for single element analysis: 615 SEK. Subsequent elements: 230 SEK/element. Request a quote when ordering of more than 5 elements.
More elements can be added, contact us for price information.
Price for single element analysis: 480 SEK. Additional elements are available on request. Price: 190 SEK/supplementary element.
Please contact us for more information about filter types
Analysis of substance: | Report limit: |
---|---|
Cr6+, chromium(VI) | 0.3 µg total |
A-Cr(VI) in inhalable dust on filter
Package info
955 SEK / sample10 work days
1 work day
1
Air/Work environment
Elements
PVC filter in monitor for inhalable dust, 25 mm (for hexavalent chromium) incl. sample holder
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Organic compounds / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
dichloromethane | 0.2 µg total |
trichloromethane (chloroform) | 0.2 µg total |
tetrachloromethane | 0.2 µg total |
1,1-dichloroethane | 0.2 µg total |
1,2-dichloroethane | 0.2 µg total |
1,1,1-trichloroethane | 0.2 µg total |
1,1,2-trichloroethane | 0.2 µg total |
1,2-dichloropropane | 0.2 µg total |
1,1-dichloroethene | 0.2 µg total |
cis-1,2-dichloroethene | 0.2 µg total |
trans-1,2-dichloroethene | 0.2 µg total |
trichloroethene | 0.2 µg total |
tetrachloroethene | 0.2 µg total |
Menu A1 Chlorinated aliphatics (absorption tubes)
Package info
2 060 SEK / sample10 work days
10 work days
1
Air/Work environment
Organic compounds
charcoal sorbent tube for solvents
GC-MS
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
Pumped sampling.
Analysis of substance: | Report limit: |
---|---|
dichloromethane | 0.2 µg total |
trichloromethane (chloroform) | 0.2 µg total |
tetrachloromethane | 0.2 µg total |
1,2-dichloroethane | 0.2 µg total |
1,1,1-trichloroethane | 0.2 µg total |
1,2-dichloropropane | 0.2 µg total |
1,1-dichloroethene | 0.2 µg total |
cis-1,2-dichloroethene | 0.2 µg total |
trans-1,2-dichloroethene | 0.2 µg total |
trichloroethene | 0.2 µg total |
tetrachloroethene | 0.2 µg total |
Menu A1 Chlorinated aliphatics (Radiello)
Package info
2 060 SEK / sample10 work days
10 work days
1
Air/Work environment
Organic compounds
Radiello for solvents
GC-MS
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
Passive sampling.
Analysis of substance: | Report limit: |
---|---|
dichloromethane | 0.2 µg total |
trichloromethane (chloroform) | 0.2 µg total |
tetrachloromethane | 0.2 µg total |
1,1-dichloroethane | 0.2 µg total |
1,2-dichloroethane | 0.2 µg total |
1,1,1-trichloroethane | 0.2 µg total |
1,1,2-trichloroethane | 0.2 µg total |
1,2-dichloropropane | 0.2 µg total |
1,1-dichloroethene | 0.2 µg total |
cis-1,2-dichloroethene | 0.2 µg total |
trans-1,2-dichloroethene | 0.2 µg total |
trichloroethene | 0.2 µg total |
tetrachloroethene | 0.2 µg total |
vinyl chloride | 0.2 µg total |
Menu A1 Chlorinated aliphatics + vinyl chloride (absorption tubes)
Package info
2 530 SEK / sample10 work days
10 work days
1
Air/Work environment
Organic compounds
charcoal sorbent tube for solvents
GC-MS
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
Pumped sampling.
Analysis of substance: | Report limit: |
---|---|
monochlorobenzene | 0.2 µg total |
1,2-dichlorobenzene | 0.2 µg total |
1,3-dichlorobenzene | 0.2 µg total |
1,4-dichlorobenzene | 0.2 µg total |
dichloromethane | 0.2 µg total |
dibromochloromethane | 0.2 µg total |
bromodichloromethane | 0.2 µg total |
trichloromethane (chloroform) | 0.2 µg total |
tetrachloromethane | 0.2 µg total |
1,2-dichloroethane | 0.2 µg total |
1,2-dibromoethane | 0.2 µg total |
1,1,1-trichloroethane | 0.2 µg total |
trichloroethene | 0.2 µg total |
tetrachloroethene | 0.2 µg total |
Menu A2 Halogenated volatile compounds (absorption tubes)
Package info
2 340 SEK / sample10 work days
10 work days
1
Air/Work environment
Organic compounds
charcoal sorbent tube for solvents
GC-MS
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
Pumped sampling.
Analysis of substance: | Report limit: |
---|---|
benzene | 0.1 µg total |
toluene | 0.2 µg total |
ethylbenzene | 0.2 µg total |
m/p-xylene | 0.1 µg total |
o-xylene | 0.1 µg total |
Menu A3 Aromatics (absorption tubes)
Package info
1 960 SEK / sample10 work days
10 work days
1
Air/Work environment
Organic compounds
charcoal sorbent tube for solvents
GC-MS
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
Pumped sampling.