Packages: 4
Sample type: Air/Work environment
Analysis type: Asbestos and fibers
Asbestos and fibers / Air/Work environment
Analysis of substance: | Report limit: |
---|---|
fibers |
A-1a Fiber counting in filter samples
Package info
1 850 SEK / sample15 work days
6
Air/Work environment
Asbestos and fibers
recommended volume 100-500 liters, flow rate 2 l/min
mixed cellulose filter
Polarization microscopy (PLM) with phase contrast
No
Yes
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
Recommeded sampling volume is given by client when analysis is ordered
Analysis of substance: | Report limit: |
---|---|
Asbestos fibers | 0,01 fibre/cm3 |
A-2a Asbestos fiber counting and identification on air filter
Package info
2 140 SEK / sample10 work days
Same day
6
Air/Work environment
Asbestos and fibers
Recommended volume 960L
Polycarbonate filter in monitor for SEM, 25 mm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Read more about asbestos at asbestos-laboratory.com.
Analysis of substance: | Report limit: |
---|---|
Synthetic inorganic fibers | 4 fibres/mm^2 |
Special fibres | 4 fibres/mm^2 |
Ceramic fibers | 4 fibres/mm^2 |
Asbestos fibers | 4 fibres/mm^2 |
A-2f Fiber counting (incl. asbestos) and identification on air filter
Package info
2 140 SEK / sample10 work days
Same day
6
Air/Work environment
Asbestos and fibers
recommended volume 150-400 liters
Polycarbonate filter in monitor for SEM, 25 mm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Read more about asbestos at asbestos-laboratory.com.
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. The fiber types are: Synthetic inorganic fibres, cheramic fibres, special fibres, asbestos fibres.