Results: 16
Analysis type: >
Query: microplastic
Analysis of substance: | Report limit: |
---|---|
A-4a Particle determination, quantitative, on filter samples (concentration, size and type)
Package info
3 560 SEK / sample10 work days
Same day
6
Air/Work environment
Microplastics and particles
Recommende volume 500-1500 liters
Polycarbonate filter in monitor for SEM, 25 mm
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
Analysis of substance: | Report limit: |
---|---|
A-4b Particle determination, qualitative, in material samples or on tape (identification of different particle types)
Package info
2 460 SEK / sample10 work days
Same day
6
Waste/construction material
Microplastics and particles
5-10 cm
ALS Sampling tape
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
The analysis is qualitative and is used to identify what particle types are presenr in dust (or material). The particles are divided into groups depending on their composition. This can be used to look for certain particles or find out the origin.
Analysis of substance: | Report limit: |
---|---|
<1 µm | % |
1-2 µm | % |
2-5 µm | % |
5-10 µm | % |
10-20 µm | % |
>20 µm | % |
A-4c Particle size distribution
Package info
3 180 SEK / sample10 work days
Same day
6
Waste/construction material
Microplastics and particles
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
The analysis is for particles in size generally being between >0.1 och <100 µm. For particle sizes outside this area other analysis are needed. The results are presented in table both in amount% and weight%
Analysis of substance: | Report limit: |
---|---|
dust | 0.1 mg total |
A-4d Total dust, excl. filter
Package info
360 SEK / sample10 work days
1 work day
6
Air/Work environment
Microplastics and particles
mixed cellulosa filter, pre-weighed, 25/37 mm or filter for inhalable dust, pre-weighed, 25 mm or filter for cyclone, pre-weighed, 25/37 mm Casella alt. 25/37 mm SKC.
Weighing
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Sampling instructions
Additional cost for filter.
Analysis of substance: | Report limit: |
---|---|
A-4e Semi-quantitative SEM/EDS analysis
Package info
1 560 SEK / sample10 work days
Same day
6
Waste/construction material
Microplastics and particles
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
The analysis is used to identify and quantify the elements in a material. Elements with atom number lower than 6 can not be identified.
The detection limit for each element is usually approximately 0.1 %, but can be significantly increased depending on the material.
Analysis of substance: | Report limit: |
---|---|
A-4f Photographs from SEM
Package info
740 SEK / sample10 work days
Same day
6
Waste/construction material
Microplastics and particles
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Price is per picture
Photography per SEM. Please specify the magnification between 50x and 10000x
Analysis of substance: | Report limit: |
---|
A-4g Particle determination, qualitative, in water (identification of different particle types)
Package info
2 460 SEK / sample10 work days
Same day
6
Water
Microplastics and particles
250 ml
250 ml glass bottle
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
The analysis is qualitative and is used to identify what particle types that occurs in the sample.
Analysis of substance: | Report limit: |
---|---|
quartz | 5 µg/filter |
A-5a Quartz in respirable dust on filter samples, FTIR
Package info
720 SEK / sample10 work days
4 work days
6
Air/Work environment
Microplastics and particles
filter for cyclone (mixed cellulosa) in SKC/Casella cyclone, pre-weighed/unweighed, 25/37mm
FTIR
Yes, Express tariff 3: 4 days +100%; 5 days +75%; 6 days +40%; 7 days +30%; 8 days +20%
Yes
Sampling instructions
Recommended flow rate 2.2-2.5 l/min, sampling time 8 hrs.
When air volume is submitted, total amount as well as and concentration is reported.
Analysis of substance: | Report limit: |
---|---|
A-5c Quartz, tridymite, and cristobalite on filter samples
Package info
3 630 SEK / sample6
Air/Work environment
Microplastics and particles
PVC filter in SKC-monitor for respirable dust, 25 mm (for quartz, tridymite and kristobalit) incl. sample holder
XRD
Sampling instructions
Minimum sampling volume: 100 l.
Analysis of substance: | Report limit: |
---|---|
A-5d Determination of quartz content in material samples
Package info
4 240 SEK / sample6
Waste/construction material
Microplastics and particles
XRD
Analysis of substance: | Report limit: |
---|---|
quartz | 10 µg/filter |
A-5f Determination of respirable quartz in material samples (incl. Andreassen sieve analysis)
Package info
5 570 SEK / sample15 work days
6
Waste/construction material
Microplastics and particles
10 g
Andreassen's sieving, XRD
Analysis of substance: | Report limit: |
---|
A-7m Identification of polymers
Package info
1 560 SEK / sample6
Products and chemicals > Plastic
Microplastics and particles
2 fibres or >25 µm
FTIR
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Identification of polymers.
Analysis of substance: | Report limit: |
---|---|
Acrylonitrile Butadiene Styrene Copolymer (ABS) | |
Polyamide (PA) | |
Butadiene Rubber (BR) | |
Polycarbonate (PC) | |
Polyethylene (PE) | |
Polyethylene Terephthalate (PET) | |
Polymethyl Methacrylate (PMMA) | |
Polypropylene (PP) | |
Polystyrene (PS) | |
Polytetrafluoroethylene (PTFE) | |
Polyurethane (PU) | |
Polyvinyl Chloride (PVC) | |
Rayon | |
OTHER COMPOUNDS 1 |
A-8a Microplastics in drinking water (µFTIR)
Package info
5 030 SEK / sample20 work days
6
Water
Microplastics and particles
1 l
1 l dark glass bottle
micro-FTIR
No
Separate the glass bottle and plastic lid using an aluminium foil to prevent contamination. Screw tight.
Identification of polymers.
1 For "other compounds" only occurrence is reported, not accredited.
Analysis of substance: | Report limit: |
---|---|
Acrylonitrile Butadiene Styrene Copolymer (ABS) | |
Polyamide (PA) | |
Butadiene Rubber (BR) | |
Polycarbonate (PC) | |
Polyethylene (PE) | |
Polyethylene Terephthalate (PET) | |
Polymethyl Methacrylate (PMMA) | |
Polypropylene (PP) | |
Polystyrene (PS) | |
Polytetrafluoroethylene (PTFE) | |
Polyurethane (PU) | |
Polyvinyl Chloride (PVC) | |
Rayon | |
OTHER COMPOUNDS 1 |
A-8b Microplastics in waste water (µFTIR)
Package info
6 100 SEK / sample20 work days
6
Water
Microplastics and particles
500 ml
500 ml dark glass bottle
micro-FTIR
No
Yes
Separate the glass bottle and plastic lid using an aluminium foil to prevent contamination. Screw tight.
Identification of polymers.
1 For "other compounds" only occurrence is reported, not accredited.
Analysis of substance: | Report limit: |
---|---|
Acrylonitrile Butadiene Styrene Copolymer (ABS) | |
Nylon-6 (N-6) | |
Nylon-6,6 (N-66) | |
Polycarbonate (PC) | |
Polyethylene (PE) | |
Polyethylene Terephthalate (PET) | |
Polymethyl Methacrylate (PMMA) | |
Polypropylene (PP) | |
Polystyrene (PS) | |
Polyurethane (PU) | |
Polyvinyl Chloride (PVC) | |
Styrene Butadiene Rubber (SBR) | |
Ethylene propylene diene monomer rubber (EPDM) |
A-9a Microplastics in drinking water (Pyrolysis-GC-MS)
Package info
5 030 SEK / sample20 work days
6
Water
Microplastics and particles
1 l
1 l dark glass bottle
Pyrolysis with GC-MS
No
Separate the glass bottle and plastic lid using an aluminium foil to prevent contamination. Screw tight.
Identification of polymers.
Analysis of substance: | Report limit: |
---|---|
Acrylonitrile Butadiene Styrene Copolymer (ABS) | |
Nylon-6 (N-6) | |
Nylon-6,6 (N-66) | |
Polycarbonate (PC) | |
Polyethylene (PE) | |
Polyethylene Terephthalate (PET) | |
Polymethyl Methacrylate (PMMA) | |
Polypropylene (PP) | |
Polystyrene (PS) | |
Polyurethane (PU) | |
Polyvinyl Chloride (PVC) | |
Styrene Butadiene Rubber (SBR) | |
Ethylene propylene diene monomer rubber (EPDM) 1 |
A-9b Microplastics in waste water (Pyrolysis-GC-MS)
Package info
6 100 SEK / sample20 work days
6
Water
Microplastics and particles
500 ml
500 ml dark glass bottle
Pyrolysis with GC-MS
No
Yes
Separate the glass bottle and plastic lid using an aluminium foil to prevent contamination. Screw tight.
Identification of polymers.
1 Not accredited.