Results: 12
Analysis type: >
Query: asbestos
Analysis of substance: | Report limit: |
---|---|
asbestos | 0.1 % |
actinolite | |
amosite | |
anthophyllite | |
chrysotile | |
crocidolite | |
tremolite |
A-1b Asbestos, qualitative in material samples
Package info
710 SEK / sample5 work days
SameDay-3h
6
Waste/construction material
Asbestos and fibers
2 cm^3, more if the sample material is inhomogenous
2 x zip bag (for asbestos)
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
The analysis is qualitative, positive results are reported as "Yes", negative results as "No". Type of asbestos fiber is only reported as "detected" or "not detected".
Please inform the laboratory about which material the sample consists of.
No express fee for 5 days delivery time. Asbestos analysis ordered as ALS Quick is performed with scanning electron microscopy (SEM).
Analysis of substance: | Report limit: |
---|---|
asbestos | 0.1 % |
actinolite | |
amosite | |
anthophyllite | |
chrysotile | |
crocidolite | |
tremolite |
A-1g Asbestos, qualitative in biofuel, ash and waste
Package info
990 SEK / sample10 work days
Same day
6
Waste/construction material
Asbestos and fibers
10-50 g
Polarization microscopy (PLM) with phase contrast
No
No
Read more about asbestos at asbestos-laboratory.com.
The analysis is qualitative, positive results are reported as "Yes", negative results as "No". Type of asbestos fiber is only reported as "detected" or "not detected".
Analysis of substance: | Report limit: |
---|---|
Asbestos fibers | 0,01 fibre/cm3 |
A-2a Asbestos fiber counting and identification on air filter
Package info
2 140 SEK / sample10 work days
Same day
6
Air/Work environment
Asbestos and fibers
Recommended volume 960L
Polycarbonate filter in monitor for SEM, 25 mm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Read more about asbestos at asbestos-laboratory.com.
Analysis of substance: | Report limit: |
---|---|
asbestos | 0.1 |
actinolite | |
amosite | |
anthophyllite | |
chrysotile | |
crocidolite | |
tremolite |
A-2b Asbestos in dust
Package info
1 630 SEK / sample5 work days
SameDay-3h
6
Waste/construction material
Asbestos and fibers
5-10 cm
ALS Sampling tape
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Sampling instructions
The analysis is qualitative, positive results are reported as "YES" and negative results reported as "NO". The different types of asbestos will be reported as "detected" or "not detected".
Read more about asbestos at asbestos-laboratory.com.
Analysis of substance: | Report limit: |
---|---|
Synthetic inorganic fibers | 4 fibres/mm^2 |
Special fibres | 4 fibres/mm^2 |
Ceramic fibers | 4 fibres/mm^2 |
Asbestos fibers | 4 fibres/mm^2 |
A-2f Fiber counting (incl. asbestos) and identification on air filter
Package info
2 140 SEK / sample10 work days
Same day
6
Air/Work environment
Asbestos and fibers
recommended volume 150-400 liters
Polycarbonate filter in monitor for SEM, 25 mm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Read more about asbestos at asbestos-laboratory.com.
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
Notify which fiber types are expected in the sample. The fiber types are: Synthetic inorganic fibres, cheramic fibres, special fibres, asbestos fibres.
Analysis of substance: | Report limit: |
---|
A-2c Asbestos semi quantitative in material
Package info
5 980 SEK / sample10 work days
Same day
6
Waste/construction material
Asbestos and fibers
ca 20g, if rock crushed to below 100 µm
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
The analysis is used to control the asbestos amount between 0.1 and 2 weight%. Not possible to use with amount >5%
Analysis of substance: | Report limit: |
---|---|
fibers |
A-1a Fiber counting in filter samples
Package info
1 850 SEK / sample15 work days
6
Air/Work environment
Asbestos and fibers
recommended volume 100-500 liters, flow rate 2 l/min
mixed cellulose filter
Polarization microscopy (PLM) with phase contrast
No
Yes
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
Recommeded sampling volume is given by client when analysis is ordered
Analysis of substance: | Report limit: |
---|---|
asbestos in soil (qualitative analysis) | 0.1 % |
A-1d Asbestos in soil, qualitative
Package info
1 680 SEK / sample10 work days
1 work day
6
Soil, sludge and sediment
Other analyses
250 g dry matter
500 ml plastic jar
Yes, Expresstariff 1: SameDay +350%; Q07 +400%; Q12 300%; Q17 +200%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
Yes
Analysis of substance: | Report limit: |
---|---|
fibers | 0.1 % |
A-2d Fiber identification (fibers other than asbestos) in dust
Package info
1 630 SEK / sample10 work days
Same day
6
Waste/construction material
Asbestos and fibers
5-10 cm
ALS Sampling tape
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
The method is used to identify fibers in material samples or dust. The analysis can also be used to determine if respirable fibers are present in a material or dust sample.
Analysis of substance: | Report limit: |
---|---|
fibers | 0.1 % |
A-2d Fiber identification (fibers other than asbestos) in material
Package info
1 630 SEK / sample10 work days
Same day
6
Waste/construction material
Asbestos and fibers
2 cm^3, more if the sample material is inhomogenous
plastic bag (e.g. zip bag)
Scanning electron microscopy (SEM)
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
The method is used to identify fibers in material samples or dust. The analysis can also be used to determine if respirable fibers are present in a material or dust sample.
Analysis of substance: | Report limit: |
---|---|
A-4a Particle determination, quantitative, on filter samples (concentration, size and type)
Package info
3 560 SEK / sample10 work days
Same day
6
Air/Work environment
Microplastics and particles
Recommende volume 500-1500 liters
Polycarbonate filter in monitor for SEM, 25 mm
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
Analysis of substance: | Report limit: |
---|---|
A-4b Particle determination, qualitative, in material samples or on tape (identification of different particle types)
Package info
2 460 SEK / sample10 work days
Same day
6
Waste/construction material
Microplastics and particles
5-10 cm
ALS Sampling tape
SEM-EDS
Yes, Expresstariff 13: SameDay-3h +200%; SameDay 150%; 1 day +100%; 2 days +75%; 3 days +40%; 4 days +30%; 5 days +20%
No
Sampling instructions
Read more about asbestos at asbestos-laboratory.com.
The analysis is qualitative and is used to identify what particle types are presenr in dust (or material). The particles are divided into groups depending on their composition. This can be used to look for certain particles or find out the origin.